AR# 29586

9.2i EDK, MPMC v3.00a - ERROR:MDT - issued from TCL procedure "check_wr_fifo", Port 1 cannot be configured to be Read-Only when C_XCL1_WRITEXFER > 0

Description

When generating the hardware or simulation files for a MPMC EDK design, I receive the following error, even when not using XCL PIMs. How do I resolve it? 

 

Running DRC Tcl procedures for OPTION IPLEVEL_DRC_PROC... 

ERROR:MDT - issued from TCL procedure "check_wr_fifo" line 12 

mpmc0 (mpmc) - 

Port 1 cannot be configured to be Read-Only when C_XCL1_WRITEXFER > 0. 

 

Running UPDATE Tcl procedures for OPTION SIMGEN_SYSLEVEL_UPDATE_PROC...

Solution

To work around this issue, set the C_XCL<portnum>_WRITEXFER parameter to 0 for the port that fails the error. 

 

PARAMETER C_XCL1_WRITEXFER = 0 

 

Also, if using read-only ports, be sure to set the MPMC training port to a writeable PIM port; in this case, PIM #4. 

 

PARAMETER C_WR_TRAINING_PORT = 4 

 

This issue is planned to be fixed in EDK 10.1i.