AR# 30661

10.1 EDK - After installing the Bus Functional Model (BFM) kit, I get a lot of errors when I launch XPS

Description

After installing the Bus Functional Model (BFM) kit, I get a lot of errors when I launch XPS: 

 

"ERROR:MDT - C:\XilinxTools\10.1\EDK\hw\XilinxBFMinterface\pcores\plb_master_bfm_v1_00_a\data\plb_master_bfm_v2_1_0.mpd line 24 Value of parameter PLB_MASTER_SIZE of type std_logic_vector must start with prefix 0x or 0b 

ERROR:MDT - C:\XilinxTools\10.1\EDK\hw\XilinxBFMinterface\pcores\plb_master_bfm_v1_00_a\data\plb_master_bfm_v2_1_0.mpd line 24 Invalid value 01 for parameter PLB_MASTER_SIZE 

:"

Solution

These error messages will go away on subsequent invocations of XPS. A new BFM Kit will be available to download when EDK 10.1 SP1 is available. BFM simulation will not work until the update is downloaded.

AR# 30661
Date Created 06/16/2008
Last Updated 05/22/2014
Status Archive
Type General Article