UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 3123

CPLD XC9500/XL/XV CoolRunner-II/XPLA3 - How are the initial states of flip-flops determined on Xilinx CPLDs?

Description

I want the power-up state of a flip-flop to be a logic High ("1"). What type of flip-flop should I use to achieve this? Is there a property that I can attach to a flip-flop so it powers up into a "1" state?

Solution

When the default software settings are used, flip-flops are initialized with a "0." However, when you add the attribute "INIT=S," any flip-flop with this attribute powers up in the "1" state.

For example, with a flip-flop instance named "TEST," add the following to your UCF:

INST TEST INIT=S;

A global setting in the software enables you to set all registers to initialize to a "1," "0," or "FPGA Equivalent." The first two settings are self-explanatory. "FPGA Equivalent" means that if there is a register in your design that is using a Preload signal but no Clear signal, this register will initialize itself with a "1" on power up. This setting is called "Default Power-up Value of Registers" and is located under the Basic tab in the "Implement Design" preferences.

In your ABEL code, you can add the following:

xilinx property 'init=s reg_name' ;

Also, add one of the following (depending on whether the register is a node or drives an output pin):

reg_name PIN istype 'reg_name default_1'; // or default_0

reg_name NODE istype 'reg_name default_1'; // or default_0

NOTE: The second line is necessary to ensure proper register initialization for functional simulation.

You can verify the register initial states by looking at the fitter report (design.rpt):

ISE Version 8.x,7.x

In the HTML report, look for the section labeled Logic. There is a column for Reg Init State. Cross-reference the row (register name) with this column to identify the power-up state for that register.

ISE Version 6.x, 5.x

Look for the section labeled: "Resources Used by Successfully Mapped Logic." There is a column for "Reg Init State." Cross-reference this column with the signal name (row) to identify the power-up state of each register.

ISE Version 4.x

- All registered equations have a .PRLD (abbreviation for "Preload") extension.

- If the .PRLD extension equals GND, the register initializes to "0."

- If the .PRLD extension equals VCC, the register initializes to "1."

For other common CPLD questions, see the CPLD FAQ at: (Xilinx Answer 24167).