AR# 32112: 11.1 Release Note - Timing Analyzer/trce - Why do I have hold analysis in my TWR? I did not see this in previous versions of TRCE
AR# 32112
|
11.1 Release Note - Timing Analyzer/trce - Why do I have hold analysis in my TWR? I did not see this in previous versions of TRCE
Description
Keywords: change, report size, increase
Why are my TWR files significantly larger when I run timing analysis in 11.1?
I see Hold Analysis being done in my timing reports by default. I never saw this behavior in previous versions of TRCE. Why do I see hold analysis when I do not have any hold violations?
Solution
The default behavior of TRCE has changed in 11.1 to report hold analysis by default. This is known as the "Fast Paths" option in the GUI, and "-fastpaths" when running from command line. This was an intended change and is as expected.