AR# 32308: 10.1.03 ISE - Error:Xilinx ISE has stopped working
AR# 32308
|
10.1.03 ISE - Error:Xilinx ISE has stopped working
Description
When I try to start up the ISE 32-bit and 64-bit version, I see an error. Windows says (in 5 seconds of booting) Xilinx ISE has stopped working.
------------------------
The Error Message
------------------------
64-bit
Problem signature: Problem Event Name: APPCRASH Application Name: _pn.exe Application Version: 1.0.0.1 Application Timestamp: 48ab97a5 Fault Module Name: libScript_Interp.dll Fault Module Version: 0.0.0.0 Fault Module Timestamp: 48897048 Exception Code: c0000005 Exception Offset: 0000000000001bf5 OS Version: 6.0.6001.2.1.0.256.4 Locale ID: 1033 Additional Information 1: 0b98 Additional Information 2: d32576b6a42caf169c692c459d588845 Additional Information 3: 2d74 Additional Information 4: 5ea240b120bac2748c4a5553519b592b
32-bit version
Problem signature: Problem Event Name: APPCRASH Application Name: _pn.exe Application Version: 1.0.0.1 Application Timestamp: 48aba92c Fault Module Name: libScript_Interp.dll Fault Module Version: 0.0.0.0 Fault Module Timestamp: 48897e78 Exception Code: c0000005 Exception Offset: 000018db OS Version: 6.0.6001.2.1.0.256.4 Locale ID: 1033 Additional Information 1: 49b4 Additional Information 2: 53b9db0ea92787b594c730768206c926 Additional Information 3: 179f Additional Information 4: 81836016ec7e90d7d06228c13b494949
Solution
To get the ISE work, follow the steps below:
- Launch the 32-bit version of Project Navigator. - From menu bar, select Edit->Preferences. - In the "Category" column, select the "HTML Browser" category. - In the "HTML Browser" section, change the option from Embedded to External/System and click OK.