AR# 33502

11.1 RTL/Technology Viewer - The Technology Viewer is not updating the schematic correctly after first run

Description

I open the Technology view of my design, then I make a design change and run the View Technology Schematic process again.

The new Technology view opens, but I cannot see the changes I have made.

The "<design>.ngc" file has been updated.

Running Clean-Up Project Files does correct the problem.

Solution

If the Technology Viewer remains open when the new run of "View Technology Schematic" is started, the Technology Viewer incorrectly caches and holds on to the original design. 

At this point, you should close and open Project Navigator again to see the altered design in the viewer.

This issue has been resolved in ISE software update 11.2.

AR# 33502
Date Created 09/14/2009
Last Updated 03/02/2015
Status Active
Type General Article
Tools
  • ISE Design Suite - 11.1