AR# 35764

12.1 EDK - "ERROR:EDK - microblaze_0 (microblaze) - can't read "limits": no such variable"

Description

I uses MicroBlaze v7.30a on an Automotive Spartan-6 device. When trying to configure MicroBlaze, the following Error Message is displayed in the bottom of the MicroBlaze configuration GUI:

"ERROR:EDK - microblaze_0 (microblaze) - can't read "limits": no such variable"

Solution

Only those device falimies that are set to "PRODUCTION" with the option ARCH_SUPPORT_MAP in the MPD file can be configured with the MicroBlaze "Configure IP" GUI.

Those devices that are set to "PRE_PRODUCTION" are not supported.
AR# 35764
Date Created 05/19/2010
Last Updated 05/19/2012
Status Archive
Type Error Message
Tools
  • EDK - 12.1