AR# 42482

Soft Error Mitigation Controller v2.1 - Hold time violations in PAR and TRCE when targeting Virtex-6 LX760 -1L

Description

Known Issue: v2.1

When running the implementation tools on the SEM controller and accompanying example design, and targeting Virtex-6 LX760 -1L devices, hold time violations may occur in PAR and TRCE.

Solution

To resolve this issue, Run PAR with extra effort switches:

 par -ol high -xe n

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
42519 Soft Error Mitigation Controller v2.1 - Release Notes and Known Issues N/A N/A
AR# 42482
Date 09/12/2014
Status Active
Type Release Notes
Devices
Tools
IP