AR# 42498

13.1 ISE Simulator - Envoking Console and Compilation Log irregularities in ISE Simulator

Description

On opening ISE Simulator, the "Console" and "Compilation Log" windows are not always opened by default. One can use the "View" menu -> "Panels" feature to do this. Some irregularities have been seen when launching these to windows in ISE Simulator.

On selecting the "Views" -> "Panels" list, "Console" may be listed at the bottom of the list, selecting this will display the "Compilation Log" as opposed to the "Console" window. Likewise, if the "Compilation Log" is listed at the bottom of the list and is selected, the "Console" will open.

Solution

To work around the issue, you need to reproduce the steps above and the correct windows will open.For example,go back into "Views" -> "Panels"; if "Console" was on the bottom previously and was selected, "Compilation Log" will now be listed on the bottom and "Console" will be second from bottom on the list. Select "Console" and the "Console" will open. The same is true when the "Compilation Log" was initially on the bottom and the "Console" previously opened.

A CR has been filed to fix this is a future release.