Description

When programming a 7 series device with the iMPACT tool, programming is reported as successful, but the device is unresponsive, and I see errors in the log file such as:

...

'1': Configuration data download to FPGA was not successful. Error detected inboot history register, please check your configuration setup and mode settings.
done.
INFO:Cse - Error shows in the status register, CRC Error bit is NOT 0.
INFO:Cse - Error shows in the status register, release done bit is NOT 1.
INFO:Cse - Status register values:
INFO:Cse - 1000 0000 0000 0000 0000 0000 0000 0000
Match_cycle = NoWait.
Match cycle: NoWait
LCK_cycle = NoWait.
LCK cycle: NoWait
INFO:iMPACT - '1': Checking done pin....done.
'1': Programmed successfully.
PROGRESS_END - End Operation.

Is the device configured correctly?

Solution

This message is incorrect. The iMPACT tool is not detecting the configuration status correctly. Check the device status register to determine if the configuration has completed correctly.

To check the device status register:

1. Select the device in the Boundary Scan Window.
2. Go to Debug menu.
3. Read Device Status.

To determine what different values in the Status Register mean, see (Xilinx Answer 34909).

This issue will be resolved in Vivado 2013.1 for 7 series devices.

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
47890 14.x iMPACT - Known Issues for the iMPACT 14.x tools N/A N/A
40503 13.x iMPACT - Known Issues for the iMPACT 13.x Software N/A N/A

Associated Answer Records

Answer Number Answer Title Version Found Version Resolved
40503 13.x iMPACT - Known Issues for the iMPACT 13.x Software N/A N/A
AR# 43150
Date Created 07/18/2011
Last Updated 03/27/2013
Status Active
Type General Article
Devices
  • Artix-7
  • Kintex-7
  • Virtex-7
  • Virtex-7 HT
Tools
  • ISE Design Suite - 13.2
  • ISE Design Suite - 13.1
  • ISE Design Suite - 13.3
  • More
  • ISE Design Suite - 13.4
  • ISE Design Suite - 14.1
  • Less