ChipScope Analyzer 13.2 - CSV Logging for System Monitor Labels Columns Incorrectly

Description

In the ChipScope Analyzer 13.2, there is a known issue with CSV logging for the System Monitor. When the CSV logging option is selected, it swaps the VCCAUX columns with the VCCINT columns.

Solution

The values are correct. To display the information properly, the only change you need to make is to swap the VCCAUX column headings with the corresponding VCCINT headings. The next table maps the VCCAUX headings that correspond to the column headings in the CSV file from the System Monitor. Swap the VCCAUX headings on the left with the corresponding heading on the right.

VCCAUX Supply Present (V) VCCINT Supply Present (V)
VCCAUX Supply Device Max VCCINT Supply Device Max
VCCAUX Device Min VCCINT Supply Device Min
VCCAUX Supply Sampled Max VCCINT Supply Sampled Max
VCCAUX Supply Sampled Min VCCINT Supply Sampled Min
VCCAUX Supply Window Average VCCINT Supply Window Average
VCCAUX Supply Window Max VCCINT Supply Window Max
VCCAUX Supply Window Min VCCINT Supply Window Min