UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 44697

MIG 7 Series - How to use DIFF_TERM_SYSCLK and DIFF_TERM_REFCLK parameters

Description

MIG allows the user to choose their desired input clock configuration as single-ended or differential. However, this selection affects both the system clock and theIDELAY control clock. In some cases, a user may wish to have separate input clock configurations for both. To do this the user must manually modify the DIFF_TERM_SYSCLK and DIFF_TERM_REFCLK in the top-level module.

Solution

DIFF_TERM_SYSCLK defines the differential termination for System clock input pins and can be assigned to "TRUE" for differential or "FALSE" for single-ended.

DIFF_TERM_REFCLK defines the differential termination for IDELAY reference clock input pinsand can be assigned to "TRUE" for differential or "FALSE" for single-ended.