General Description:
Using a complex condition check inside an always block in Verilog is not supported by
FPGA Express. For example, the following code will result in the error below:

<PRE>
always @( negedge input1 or negedge input2 or posedge clock )
begin
if ( ~input1 | ~input2 )
begin
output1 <= 1'b1;
output2 <= 1'b0;
end
else
begin
output1 <= input1;
output2 <= input2 & input1;
end
end
</PRE>

Error: The expression in the reset condition of the 'if' statement in this 'always' block can
only be a simple identifier or its negation (near symbol ")" on line 13 in file test.v) (VE-92)

Solution

Perform the combinatorial logic outside the always block, then use that intermediate signal
in the sensitivity list of the always block.


assign temp = ~input1 | ~input2;
always @( posedge temp or posedge clock )
begin
if ( temp )
begin
output1 <= 1'b1;
output2 <= 1'b0;
end
else
begin
output1 <= input1;
output2 <= input2 & input1;
end
end