AR# 46460

13.4 - ModelSim Error when running DS824 - AXI Bus Functional Models v1.9 example scripts

Description

When running the .do files delivered with DS824, the following error occurs:

# vsim -pli libxil_vsim.dll -t 1ps -novopt work.logibayer_tb
# Loading ./libxil_vsim.dll
# ** Error: (vsim-3193) Load of "./libxil_vsim.dll" failed: DLL dependent library not found.
#
# ** Error: (vsim-PLI-3002) Failed to load PLI object file "./libxil_vsim.dll".
#
#          Region: /
# // ModelSim PE 10.1 Dec 6 2011

The libraries have been successfully complied.

Solution

This error occurs when the Xilinx Environment has not been set up correctly.

 

The XILINX env variable must be set correctly. 


In Windows, %XILINX% can be set by running the settings32.bat or settings64.bat file in the ISE_DS directory of the installed version.


Alternatively, invoke ModelSim from the ISE Design Suite Command Prompt.

AR# 46460
Date Created 02/23/2012
Last Updated 09/26/2014
Status Active
Type General Article
Tools
  • ISE Design Suite - 13.3
  • ISE Design Suite - 13.4