AR# 47592

Zynq-7000 AP SoC, Power - Static Current for CES devices is Higher than Reported in XPE Power Estimator

Description

The XC7Z020 and XC7Z045 CES devices static current can be notably higher than what is reported in the XPE Power Estimator.

Note: XPE version 14.5/2013.1 or later is recommended with production silicon (no adjustments are needed).

Solution

For the XC7Z020 CES devices, the potential increase for the static current for each power supply rail is outlined in the table below:

Power Supply XC7Z020 CES Static Current vs. reported by XPE (1)
VCCPINT 50% (2)
VCCPAUX 25%
VCCINT 25%
VCCAUX 50%
VCCAUX_IO 25%
VCCO_DDR 25%
VCCO_MIO{0, 1} 25%
VCCADC 25%
VMGTAVCC 25%
VMGTAVTT 25%
VMGTAVCCAUX 25%

For the XC7Z045 CES devices collectively, the overall static current does not exceed 25% over XPE. Individually, for each rail the potential increase for the static current is shown in the table below:

Power Supply XC7Z045 CES Static Current vs. reported by XPE (1)
VCCPINT 75% (2)
VCCPAUX 25%
VCCINT 15%
VCCAUX 75%
VCCAUX_IO 75%
VCCO_DDR 25%
VCCO_MIO{0, 1} 25%
VCCADC 75%
VMGTAVCC 75%
VMGTAVTT 25%
VMGTAVCCAUX 25%

Footnotes:

(1) The percentages shown are based on comparisons of static current reported in XPE version14.2.
(2) XPE version 14.4 (and newer) have increased the static current reported on the Vccpint rail, therefore the increase percentages shown for CES material in the tables above will be conservative.

Impact: Minor. This higher amount is expected of ES devices and it is expected to become lower as the fab process is tuned for production silicon.

Work-around: None.

Configurations Affected: All.

Device Revision(s) Affected: Refer to (Xilinx Answer 47916) - Zynq-7000 AP SoC Devices - Silicon Revision Differences