A project containing a ChipScope ILA or AXI monitor fails Platgen in EDK 14.3 with the error below:
ERROR:EDK:440 - platgen failed with errors!
make: *** [implementation/system_proc_sys_reset_0_wrapper.ngc] Error 2
Done!
In EDK 14.4, the error is slightly different:
ERROR:EDK -
kc705_ddr3.mhs line 250 - PARAMETER C_NUM_DATA_SAMPLES has value 512 which does not fall in the range
(1024, 2048,4096,8192,16384,32768,65536,131072), specified in MPD
How can I fix this issue?
This is a known issue when the minimal signals are set to 512.
To fix the problem:
In the Configure IP screen, change the "Number of Data Samples Captured Per Trigger Match" from 512.
Any other value is supported.
AR# 53486 | |
---|---|
Date | 09/15/2014 |
Status | Active |
Type | General Article |
Tools |