7-Series GTH Wizard 2.3 - ISE14.3 - missing connection in GTH instance, when TX is not used and RX fabric interface is 80 bits

Description

When using an 80-bit fabric interface RX channel and a disabled TX channel (or enabled TX channel but different fabric interface: 64 bit), an incorrect GT file is generated.
The Wizard incorrectly leaves the GTHE2_CHANNEL instance ports RXCHARISK and RXDISPERR open.

Rxdata_out_i is correctly built:

------------- GT RXDATA Assignments for 80 bit datapath -------

rxdata_out_i <= (rxdisperr_i(7) & rxcharisk_i(7) & rxdata_i(63 downto 56) &
rxdisperr_i(6) & rxcharisk_i(6) & rxdata_i(55 downto 48) &
rxdisperr_i(5) & rxcharisk_i(5) & rxdata_i(47 downto 40) &
rxdisperr_i(4) & rxcharisk_i(4) & rxdata_i(39 downto 32) &
rxdisperr_i(3) & rxcharisk_i(3) & rxdata_i(31 downto 24) &
rxdisperr_i(2) & rxcharisk_i(2) & rxdata_i(23 downto 16) &
rxdisperr_i(1) & rxcharisk_i(1) & rxdata_i(15 downto 8) &
rxdisperr_i(0) & rxcharisk_i(0) & rxdata_i(7 downto 0) );

But wires are not connected to GTHE2_CHANNEL instance:

----------------------- Receive Ports - 8b10b Decoder ----------------------
RXCHARISK => open,
RXDISPERR => open,


This causes received data to be incorrect.

Solution

Please connect the RXCHARISK and RXDISPERR ports to the wires:

----------------------- Receive Ports - 8b10b Decoder ----------------------
RXCHARISK => rxcharisk_i,
RXDISPERR => rxdisperr_i,