UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 56074

iMPACT 13.x/14.x - Parallel Cable IV is recognized as Cable III

Description

The parallel port of a laptop is usually expanded by a dock. When Parallel Cable IV is plugged, it is recognized as Cable III in iMPACT. If using cable setup to select PC4 and a different cable speed, the following message is shown:

// *** BATCH CMD : setCable -port lpt1
Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
 Driver windrvr6.sys version = 10.2.1.0. WinDriver v10.21 Jungo (c) 1997 - 2010 Build Date: Aug 31 2010 x86_64 64bit SYS 14:14:44, version = 1021.
 LPT base address = 0378h.
 ECP base address = FFFFFFFFh.
Cable connection established.
Connecting to cable in compatibility mode.

Solution

For Win7/WinXP,  add this environmental variable:

XIL_IMPACT_ENV_LPT1_ECP_ADDRESS = 0778

Reopen iMPACT, PC4 can be recognized properly like this:

Connecting to cable (Parallel Port - LPT1).
Checking cable driver.
 Driver windrvr6.sys version = 10.2.1.0. WinDriver v10.21 Jungo (c) 1997 - 2010 Build Date: Aug 31 2010 x86_64 64bit SYS 14:14:44, version = 1021.
 LPT base address = 0378h.
 LPT1 Ecp Address set from env variable = 778.
 ECP base address = 0778h.
 ECP hardware is detected.
Cable connection established.
Connecting to cable (Parallel Port - LPT1) in ECP mode.
Checking cable driver.
 Driver xpc4drvr.sys version = 1.0.4.1. LPT base address = 0378h.
 LPT1 Ecp Address set from env variable = 778.
 Cable Type = 1, Revision = 3.
 Setting cable speed to 5 MHz.
Cable connection established.
PROGRESS_END - End Operation.
Elapsed time =      3 sec.
AR# 56074