2013.3 Vivado IP_ILA - The ILA core captures incorrect data if the trigger position is set to 0

Description

If a trigger position is set to 0, the ILA core of data depth N captures incorrect data (all zeros) on N-1 samples.

If the trigger setup is set to any value except 0, incorrect data is seen on the sample 0.

Solution

This issue is planned to be fixed in a future revision of the tools.