AR# 58043

Soft Error Mitigation Controller – Setup time violation if using SEM v4.0 rev 2 IP with error injection shim set to chipscope

Description

If SEM v4.0 rev 2 is configured with injection enabled and injection shim = chipscope, and a ChipScope core is generated for inclusion in the SEM example design, then a setup time violation may be seen when implementing the design in the Vivado 2013.3 tool.

CRITICAL WARNING: [Route 35-39] The design did not meet timing requirements. Please run report_timing_summary for detailed reports.

Solution

Instead of using ChipScope, use the Vivado Lab Tools IP. Refer to (Xilinx Answer 54460) for instructions to adopt the Vivado Lab Tools IP.