1.5i Map - A case has been seen where -pr b option drops an inversion between flop and BUFT.

Description

Keywords: MAP, -pr b, BUFT

Urgency: standard

General Description:
If a Virtex design has a flip flop connected to an inverter and the output of the inverter enables a BUFT, the design is mapped with the correct logic. When the -pr b option is used to push the flop into the IOB, the inveris lost, corrupting the logic.

Solution

This problem has been corrected for version 2.1i.