UPGRADE YOUR BROWSER

We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 58610

2013.3 Vivado Constraints - CRITICAL WARNING: [Netlist 29-75] Setting 'PULLUP' property on 'net' objects from input source 'XDC' is not supported

Description

When I try to set a PULLUP on a net the following Critical Warning is given:

CRITICAL WARNING: [Netlist 29-75] Setting 'PULLUP' property on 'net' objects from input source 'XDC' is not supported. [./constraints.xdc:30]

The constraint in question is:

set_property PULLUP TRUE [get_nets error]


Solution

Applying PULLUP, PULLDOWN and KEEPER properties to net objects is not supported. 

Instead, port objects should be used.

For example:

set_property PULLUP TRUE [get_ports error]
AR# 58610
Date Created 12/02/2013
Last Updated 01/12/2015
Status Active
Type Error Message
Tools
  • Vivado Design Suite