Licensing - Xlicsrvrmgr gives ERROR: flxActCommonInit result 2 when creating a request for a floating server

Description

I am setting up a floating server using activation based licensing.

When going through the steps to set up the machine, creating the request causes the following error:
 
root@tardis:/home/tools/xilinx/linix_flexlm/linux_flexlm_v11.11.0/lnx64.o# ./install_fnp.sh
Installing anchor service from ./FNPLicensingService to /usr/local/share/FNP/service64/11.11.0
Checking system for trusted storage area...
Configuring for Linux, Trusted Storage path /usr/local/share/macrovision/storage...
Creating /usr/local/share/macrovision/storage...
Setting permissions on /usr/local/share/macrovision/storage...
Permissions set...

Checking system for Replicated Anchor area...
Configuring Replicated Anchor area...
Creating Replicated Anchor area...
Setting permissions on Replicated Anchor area...
Replicated Anchor area permissions set...
Configuring Temporary area...
Creating Temporary area...
Setting permissions on Temporary area...
Temporary area permissions set...
Configuration completed successfully.
root@tardis:/home/tools/xilinx/linix_flexlm/linux_flexlm_v11.11.0/lnx64.o#
However when running the Xlicsrvrmgr, I got the following:
Redhat:
[root@egad bin]# ./xlicsrvrmgr cr Xilinx_licensereq.xml
ERROR: flxActCommonInit result 2   .
Exit(2) FLEXnet initialisation error.

Solution

This error is a result of the command not being able to find the libraries necessary at runtime. 

It was found that the PATH and LD_LIBRARY_PATH environment variables did not contain a search location of the current directory (dot).

If you add/append the directory where "libXLicSrvrMgrFNP.so" is stored to PATH or LD_LIBRARY_PATH, the command will run normally.