After toggling a number of times, app_rd_data_end may become stuck high as shown in the example design simulation below:

app_rd_data_end.PNG


Solution

With controllers using a 4:1 PHY to controller clock ratio, app_rd_data_end is always asserted high along with app_rd_data_valid.

Hence this signal is not needed for user logic and can be ignored. 

For 2:1 controllers, app_rd_data_end does toggle properly on the second word returned on app_rd_data.