AR# 64513

UltraScale SEM v2.0 - Query by LFA command does not work for SSI device

Description

When targeting an SSI device (XCKU117), the Query by LFA command does not report the correct frame contents for the specified address.

Solution

This issue only applies to KU115 devices, because the only SSI device supported in this version is the KU115.

Before executing the query command, use the Translate command to translate the LFA to PFA. Then execute the Query command using the translated PFA.

AR# 64513
Date Created 05/10/2015
Last Updated 10/22/2015
Status Active
Type General Article
Tools
  • Vivado Design Suite - 2015.1
IP
  • Soft Error Mitigation