2016.2 Vivado IP FLows - ERROR: [IP_Flow 19-3439] Failed to restore IP 'clk_wiz_0' customization to its previous valid configuration

Description

In Vivado IP Integrator I have a Block Design (BD) which has a Clocking Wizard IP instance.

I update the Clocking Wizard IP instance output frequencies using a Tcl script which opens the project, reads the BD, sets the output frequency and validate the BD.

The Tcl script uses a set_property command to change the output frequency. However, I have encountered the following error message:

set_property -dict [list CONFIG.CLKOUT1_REQUESTED_OUT_FREQ {150.000}] [get_bd_cells clk_wiz_0]

ERROR: [IP_Flow 19-3439] Failed to restore IP 'clk_wiz_0' customization to its previous valid configuration.

INFO: [Common 17-17] undo 'set_property'

ERROR: [Common 17-39] 'set_property' failed due to earlier errors.

Solution

The message should be ignored. The set_property Tcl command actually sets the output frequency as specified.

This issue will be fixed in Vivado 2016.3.