AR# 68236

UltraScale DDR4 - upgrading locked IP might fail for select RDIMMs

Description

Version Found: DDR4 v2.1 (Rev. 1)

Version Resolved: See (Xilinx Answer 69035)

When upgrading a locked IP to a new version of Vivado, the following error message might be seen:

ERROR: [Mig 66-119] Phy core regeneration & stitching failed. Please check vivado.log and debug_core_synth.log files in the directory: /proj/ipmig2/rakeshb/Upgrade_Flow_testing_2016.1_to_2016.4/ddr4_cmc_50tests_upgrade/ddr4_cmc_50tests_upgrade/SN6_virtexuDDR4_926MHz_72bit_ecc_ssit_BFM_XSDB_EN/vivado/impl/SN6_virtexuDDR4_ooc_en_example/SN6_virtexuDDR4_example/SN6_virtexuDDR4_ooc_en_ex/SN6_virtexuDDR4_ex/SN6_virtexuDDR4_ex.runs/impl_1/.Xil/Vivado-29140-xhd-lin64re91/29140 to debug the problem.
Phase 1 Generate And Synthesize MIG Cores | Checksum: 16911367c

This error can occur as a result of the address width for the targeted DDR4 part changing between releases. Only the following DDR4 RDIMM parts are impacted:


  • MTA18ASF1G72PZ-2G1
  • MTA36ASF2G72PZ-2G1
  • MTA18ADF1G72PZ-2G1

Solution

If this error message is seen and you are targeting one of the impacted DDR4 RDIMM parts, then please regenerate the DDR4 IP from scratch in the new version of Vivado to resolve the issue.

Revision History:

11/17/2016 - Initial Release

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
69035 UltraScale/UltraScale+ DDR4 - Release Notes and Known Issues N/A N/A
AR# 68236
Date 01/12/2018
Status Active
Type Known Issues
Devices
  • Kintex UltraScale
  • Virtex UltraScale
Tools
  • Vivado Design Suite - 2016.4
  • Vivado Design Suite - 2017.1
IP
  • MIG UltraScale
Page Bookmarked