General Description:

When I generate STAMP data for minimum timing values in TRACE or a minimum timing report, the following error occurs:

"ERROR: Trace - Invalid speed 'min' specified on command line."

The following fatal error then occurs:

"Fatal Error: Command failed for target."

Solution

The "-s min" option is supported only in the specific family mentioned in (Xilinx Answer 4506).

You can only use the "-s min" option for fully routed designs. If a design contains any unrouted signals, this error will occur.

For more information, see (Xilinx Answer 4506) and (Xilinx Answer 6067).