AR# 9112

3.1i COREGEN - Incorrect reference to Verilog model in the .veo template for the Dual Channel NCO core.

Description

Keywords: dual, channel, nco, numerically controlled oscillator, core generator

Urgency: standard

General Description:
In the 3.1i version of the CORE Generator, the .veo template for the
Dual Channel Numerically Controlled Oscillator core for Spartan-II is
generated incorrectly.

There are two problems:

1. The path delimiters should be forward slashes, not backslashes
2. The model name is ncoiqvht.v instead of ncoiq_v1_0.v

Solution

Edit the .veo and correct the reference manually to point to
<path_to_Xilinx_installation>/verilog/src/XilinxCoreLib/ncoiq_v1_0.v.

This will be corrected in a future IP update.