AR# 9903

3.1isp2 TRCE - "Program abnormally terminated"/Dr. Watson error

Description

General Description:

When I run a design through TRCE in 3.1i with Service Pack 2 (or earlier) on a V2000E design, a Dr. Watson Error (PC) or core dump occurs.

The only error message reported is in the fe.log file, which says "Program Abnormally Terminated".

Solution

The design crashes because the DLL feedback net is driverless.

This issue was fixed in the 4.1i software.