AR# 20878

Virtex 4 Configuration Users Guide - pullup values not given for done

Description

General Description:

Figure 2-3 on page 23 and later pages show pullups on the done pin but does not indicate what the value of this pullups

Solution

The pullup value should be 330 ohms to ensure DONE pin transitions high within one startup clock cycle.

AR# 20878
Date Created 02/28/2005
Last Updated 12/15/2012
Status Active