AR# 57682

2013.3 Vivado IP-ILA - The ILA Probe_Ports(0....7) tab turns red if the 1024 Probes and Enable Capture Control option is selected


In the GUI, the Probe_Ports(0..7) tab turns red if the "Number of Probes" = 1024 and the Enable "Capture Control" option under the "General Options" tab is selected. 

A validation failed error is returned for parameter 'C Probe0 Mu Cnt(C_PROBE0_MU_CNT)' with value '2' for IP 'ila_0'. 

Validation failed for parameter 'C Probe0 Mu Cnt(C_PROBE0_MU_CNT)' with value '2' for IP 'ila_0'. Total Number of comparators of all probes cannot exceed 1024.


This issue is planned to be fixed in a future release.

In the meantime, to work around the issue, do not use the Capture Control option when the number of probes is more than 512.

AR# 57682
Date Created 09/27/2013
Last Updated 10/15/2014
Status Active
Type General Article