We have detected your current browser version is not the latest one. Xilinx.com uses the latest web technologies to bring you the best online experience possible. Please upgrade to a Xilinx.com supported browser:Chrome, Firefox, Internet Explorer 11, Safari. Thank you!

AR# 61790

7 Series MIG - DDR3 - app_rd_data_end stays high


Version Found: MIG 7 Series v2.1
Version Resolved: See (Xilinx Answer 54025)

After toggling a number of times, app_rd_data_end may become stuck high as shown in the example design simulation below:



With controllers using a 4:1 PHY to controller clock ratio, app_rd_data_end is always asserted high along with app_rd_data_valid.

Hence this signal is not needed for user logic and can be ignored. 

For 2:1 controllers, app_rd_data_end does toggle properly on the second word returned on app_rd_data.

Revision History

11/24/2014 - Initial Release

Linked Answer Records

Master Answer Records

Answer Number Answer Title Version Found Version Resolved
54025 MIG 7 Series - IP Release Notes and Known Issues for Vivado 2013.1 and newer tool versions N/A N/A
AR# 61790
Date Created 08/14/2014
Last Updated 01/09/2015
Status Active
Type Known Issues
  • MIG 7 Series