AR# 30883

10.1 iMPACT - Reading back the Status Register in iMPACT indicates all 0s

Description

Reading back the Status Register in iMPACT indicates all 0s.

Solution

Check the Security option within BitGen, if it is set to Level2 (which disables Readback and Partial Reconfiguration), then you will not be able to readback the Status Register. To enable this function, set Security to "None" and then you will be able to read the Status register.

AR# 30883
Date Created 05/01/2008
Last Updated 12/15/2012
Status Active