AR# 64512

UltraScale SEM v2.0 device and feature support guidance for Vivado 2015.1

Description

In Vivado 2015.1, the UltraScale SEM IP supports the following list of devices.
 

A subset of these devices will temporarily have limited feature support as indicated below.

these limitations are planned be removed in a future release after the solution has been tested in hardware on those devices.

Solution

The following list of devices are supported at Pre-Production without any feature restrictions:
 
  • xcku040
  • xcku060
  • xcvu095
The following device is supported at Pre-Production with no Classification support:
 
  • xcku115
The following list of devices are supported as Beta with no error injection support and no linear frame addressing support (the "Query by LFA" command and Translate command are not supported).
 
  • xcku035
  • xcku075 *this device will be canceled
  • xcvu065
  • xcvu080

Please also reference (PG187) the UltraScale Architecture Soft Error Mitigation Controller v2.0 Product Guide for details of the feature supported and not supported.

http://www.xilinx.com/support/documentation/ip_documentation/sem_ultra/v2_0/pg187-ultrascale-sem.pdf

AR# 64512
Date Created 05/10/2015
Last Updated 05/25/2015
Status Active
Type General Article
Tools
  • Vivado Design Suite - 2015.1
IP
  • Soft Error Mitigation